GHS mixture calculator: acute toxicity (ATEmix)

Enter the ingredients of your mixture to see its acute toxicity estimate and category under OSHA HazCom 2024 (US), WHMIS (Canada), EU CLP and GB CLP, side by side. The four rules share the formula but not the rules on which ingredients count, so the same mixture can land in different places. Nothing you type leaves your browser.

Your mixture

IngredientConcentration (%)What you knowValue

Result by market

Inhalation values must be for a 4-hour exposure: the rules convert 1-hour data by dividing by 2 for gases and vapours and by 4 for dusts and mists. Do that before you enter the value, and enter every ingredient in the same form and unit.

A calculation is not a classification

A signed classification also checks test data on the mixture, the bridging principles, every other hazard class and the label and SDS wording for each market. A regulatory specialist signs off every Hazline classification report and SDS.

How the calculation works

When there is no test data for the mixture and the bridging principles do not apply, all four rules use the same additivity formula:

100 / ATEmix = Σ ( Ci / ATEi )

Ci is the concentration of each counted ingredient and ATEi its acute toxicity estimate: its LD50 or LC50, or, when only its category or a range is known, the converted point estimate in the table below. If more than 10 % of the mixture is made of relevant ingredients of unknown acute toxicity, the 100 becomes 100 minus that total.

Where the four rules differ

US (HazCom 2024) Canada (HPR) EU CLP GB CLP
Ingredients with an oral or dermal LD50 above 2,000 and up to 5,000 mg/kgCountedCountedNot countedNot counted
Ingredients under 1 %Counted if there is reason to suspect they matterOnly ingredients at 1.0 % or more must be consideredCounted if there is reason to suspect they matterCounted if there is reason to suspect they matter
Unknown acute toxicity at 1 % or moreStatement on the label and SDSStatement on the labelStatement on the label and SDSStatement on the label and SDS

Category cut-offs and converted point estimates

RouteCategory 1Category 2Category 3Category 4
Oral (mg/kg)≤ 5 (0.5)> 5 to 50 (5)> 50 to 300 (100)> 300 to 2,000 (500)
Dermal (mg/kg)≤ 50 (5)> 50 to 200 (50)> 200 to 1,000 (300)> 1,000 to 2,000 (1,100)
Gases (ppmV)≤ 100 (10)> 100 to 500 (100)> 500 to 2,500 (700)> 2,500 to 20,000 (4,500)
Vapours (mg/l)≤ 0.5 (0.05)> 0.5 to 2.0 (0.5)> 2.0 to 10.0 (3)> 10.0 to 20.0 (11)
Dusts and mists (mg/l)≤ 0.05 (0.005)> 0.05 to 0.5 (0.05)> 0.5 to 1.0 (0.5)> 1.0 to 5.0 (1.5)

Converted point estimates in brackets: the value used in the formula when only an ingredient's category or range is known. See also SDS rules compared: US, Canada, EU and UK.

Mixture calculator: common questions

What is ATEmix?

ATEmix is the acute toxicity estimate of a mixture, worked out from the acute toxicity estimates (LD50 or LC50, or a converted point estimate) of its ingredients with the GHS additivity formula. It decides whether the mixture is classified for acute toxicity, and in which category, when the mixture itself has not been tested.

Why can the same mixture classify differently in the US, Canada, the EU and the UK?

All four use the same formula and the same category cut-offs, but not the same rules on which ingredients count. The US and Canada include ingredients with an oral or dermal LD50 between 2,000 and 5,000 mg/kg; the EU and GB only include ingredients that fall in Categories 1 to 4. Adding those ingredients lowers the ATEmix, so a mixture can land in Category 4 in North America and not be classified in Europe.

Is the result of this calculator a classification I can put on my SDS?

No. The formula is one step. A classification also checks test data on the mixture, the bridging principles, every other hazard class, and the label and SDS wording for each market. Hazline prepares classification reports and SDSs that a regulatory specialist signs off.

Is my formula sent anywhere?

No. The calculation runs in your browser. Nothing you type is stored or sent to Hazline or anyone else.

Sources

  • US: 29 CFR 1910.1200, Appendix A, A.1.2 (Table A.1.1), A.1.3.3, A.1.3.6 and Table A.1.2 (eCFR, up to date as of 12 Nov 2026).
  • Canada: Hazardous Products Regulations SOR/2015-17, ss. 3(1)(e) and 8.1.1 to 8.1.7 (Justice Laws, current to 19 Oct 2026).
  • EU: Regulation (EC) No 1272/2008, Annex I, 3.1.2 (Table 3.1.1), 3.1.3, Tables 3.1.2 and 3.1.3 (EUR-Lex consolidated version of 1 Jul 2026).
  • GB: Regulation (EC) No 1272/2008 as it has effect in Great Britain, Annex I, 3.1 (legislation.gov.uk revised text, 16 Nov 2026).

This calculator covers the additivity formula only. It is general information, not a classification by a qualified person or legal advice. Checked against the regulatory texts on 22 November 2026.

Free SDS checkBook a call